Publicación:
Comparison of the Friedewald and Vujovic methods with the calculated LDL concentration in a biochemical auto-analyzer; Comparación de los métodos de Friedewald y Vujovic con la concentración de LDL calculada en un autoanalizador bioquímico

dc.contributor.authorRosales-Rimache, Jaime Alonso
dc.contributor.authorApaza-Condori, Jeferson
dc.contributor.authorRabanal-Sanchez, Jhonatan
dc.contributor.authorLi, Jari
dc.contributor.authorSoncco-Llulluy, Fernando
dc.date.accessioned2025-09-05T16:32:11Z
dc.description.abstractOBJECTIVE To compare the concentration of Low-Density Lipoprotein (LDL-c) obtained using the Friedewald formula with those obtained directly with the RAYTO CHEMRAY 120 autoanalyzer. METHODS Cross-sectional study. We evaluated outpatients with a medical request for a lipid profile study (total cholesterol, triglycerides, LDL, and HDL). The analyses were carried out in a RAYTO CHEMRAY 120 autoanalyzer under the principle of spectrophotometry. We obtained LDL-c using the Friedewald and Vujovic formulas. RESULTS We evaluated 199 individuals whose direct LDL concentration averages were measured by the RAYTO CHEMRAY 120 equipment. Those calculated by the Friedewald and Vujovic formulas were 129.97 ± 32.66, 119.28 ± 30.44, and 127.01 ± 32.01, respectively, and in all cases, significant differences (P < 0.001) were observed with the RAYTO analyzer. In both cases a low positive bias was found with the RAYTO analyzer.. The Passing-Bablok and Deming's regressions showed a linear correlation between both methods (Friedewald and Vujovic) with the LDL values obtained with the Rayto autoanalyzer. CONCLUSIONS Our study found that the Friedewald and Vujovic methods are good predictors of LDL cholesterol levels and have a low level of bias. Therefore, they could be used as potential predictors. © 2024 Elsevier B.V., All rights reserved.
dc.identifier.doi10.5867/medwave.2024.04.2775
dc.identifier.scopus2-s2.0-85192625143
dc.identifier.urihttps://cris.uwiener.edu.pe/handle/001/135
dc.identifier.uuiddd2614bf-ee8b-4475-ae6e-589ced5c2785
dc.language.isoen
dc.publisherMedwave Estudios Ltda
dc.relation.citationissue4
dc.relation.citationvolume24
dc.relation.ispartofseriesMedwave
dc.relation.issn7176384
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.titleComparison of the Friedewald and Vujovic methods with the calculated LDL concentration in a biochemical auto-analyzer; Comparación de los métodos de Friedewald y Vujovic con la concentración de LDL calculada en un autoanalizador bioquímico
dc.typehttp://purl.org/coar/resource_type/c_2df8fbb1
dspace.entity.typePublication

Archivos

Colecciones