Publicación:
Electrochemical Sensitivity Improvement by the Cooperation between Pt and Ru for Total Antioxidant Evaluation in Natural Extracts

dc.contributor.authorDiniz, Gustavo Carvalho
dc.contributor.authorPinheiro Gomes, Vinicius Tribuzi Rodrigues
dc.contributor.authorde Assis, Marcelo L.
dc.contributor.authorAlejandro Figueroa, Santiago José
dc.contributor.authorFerreira Torquato, Igor
dc.contributor.authorde Freitas Borges, Luiz Gustavo
dc.contributor.authorAguilar Vitorino, Hector
dc.contributor.authorde Lima, Roberto Batista
dc.contributor.authorGarcia, Marco Aurélio Suller
dc.contributor.authorde Araujo Rodrigues, Isaide
dc.date.accessioned2025-09-05T16:33:38Z
dc.description.abstractHerein, a straightforward electrochemical method was used to evaluate the total phenolic antioxidant capacity in natural extracts prepared from pomegranate, hibiscus, and pitaya. In light of this, the well-known electrochemical index (EI), a screening protocol for natural antioxidant properties evaluation, was determined using differential pulse voltammetry. Initially considering rutin and catechin as standards, we found that the system’s sensitivity greatly increased by using platinum (Pt) and platinum/ruthenium (Pt/Ru) nanoparticles (NPs) immobilized on Vulcan XC-72 to modify screen-printed carbon electrodes (SPCEs). When such modifications were applied to natural fruit/plant extracts, their electrochemical ability proved highly superior to the bare SPCE, even considering a very small amount of materials for electrode preparation. However, with an optimized ratio, the bimetallic counterpart was more sensitive to detection. When the pomegranate extract was used, for example, EI values of 52.51 ± 6.00 and 104.79 ± 6.89 µA/V were obtained using Pt and Pt/Ru (with an optimized ratio) electrocatalysts, showing the remarkable sensitivity increase obtained in our bimetallic protocol. Thus, based on physicochemical and electrochemical characterizations, we found that the ruthenium content was essential for the achievements. In due course, XPS analysis suggested that the Pt2+/Pt0 species ratio could have improved the system’s sensitivity, which significantly changed when ruthenium was used in the material. © 2024 Elsevier B.V., All rights reserved.
dc.identifier.doi10.3390/chemosensors11060314
dc.identifier.scopus2-s2.0-85163723103
dc.identifier.urihttps://cris.uwiener.edu.pe/handle/001/347
dc.identifier.uuid0995d349-8114-46de-b037-8015191a88c0
dc.language.isoen
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.relation.citationissue6
dc.relation.citationvolume11
dc.relation.ispartofseriesChemosensors
dc.relation.issn22279040
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.titleElectrochemical Sensitivity Improvement by the Cooperation between Pt and Ru for Total Antioxidant Evaluation in Natural Extracts
dc.typehttp://purl.org/coar/resource_type/c_2df8fbb1
dspace.entity.typePublication

Archivos

Colecciones